You need to choose options for product.
Sale
-
files/pHMeter-5Points.jpg
SALIENT FEATURES:-
During the pH mode, Up to 5 points push-button calibration with auto- buffer recognition.
Selectable pH buffer standards and temperature units.
Automatically calculates and displays electrode slope after calibration.
Automatic Temp. Compensation (ATC) ensures highly accurate measurement over the entire range.
Calibration due reminder prompts you to calibrate the meter regularly.
During ORP mode, Single point offset calibration allows user adjusts displayed value to a known standard.
Absolute or Relative millivolt (R.mV) measurement provides accurate ORP readings.
Automatic endpoint function freezes the stable measured values for easy reading and recording data.
Setup menu lets user customizes buffer standards,
calibration points, stability conditions, resolution, temperature units, date and time to meet measurement requirements.
Reset function can resumes all settings to factory default values.
Expanded memory stores and recalls up to 500 readings.
Built-in real-time clock stamps stored data to meets GLP standards.
Specifications:-
Model | LMPH12 |
Make | LABMAN |
pH Range | -2.000-20.000pH |
pH Accuracy | +0.002pH |
pH Resolution | 0.001, 0.01, 0.1pH ( Selectable) |
mV Range | +1999mV |
mV Accuracy | +0.2mV |
mV Resolution | 0.1, 1mV ( Selectable ) |
Calibration | upto 5 points |
pH Buffer Option | USA (pH1.68,4.01,7.00,10.01,12.45), NIST (pH1.68,4.01,6.86,9.18,12.45) DIN (pH1.09,4.65,6.79,9.23,12.7) OR User Define |
Calibration due reminder | |
Temp. Range | 0-105°C, 32-212°F |
Temp. Accuracy | +0.5°C, +0.9°F |
Temperature Compensation | 0-100°C, 32-212°F, Automatic or Manual |
Auto-Off | Manual or Automatic (10, 20, 30 minutes after last key pressed (Selectable) |
Memory | 500 readings with date & time |
Power Supply | Adaptor, Using AC 220V,50/60Hz |
Dimensions LxWxH (mm) | 210x188x60 |
Weight | 1.2kg |
SALIENT FEATURES:-
During the pH mode, Up to 5 points push-button calibration with auto- buffer recognition.
Selectable pH buffer standards and temperature units.
Automatically calculates and displays electrode slope after calibration.
Automatic Temp. Compensation (ATC) ensures highly accurate measurement over the entire range.
Calibration due reminder prompts you to calibrate the meter regularly.
During ORP mode, Single point offset calibration allows user adjusts displayed value to a known standard.
Absolute or Relative millivolt (R.mV) measurement provides accurate ORP readings.
Automatic endpoint function freezes the stable measured values for easy reading and recording data.
Setup menu lets user customizes buffer standards,
calibration points, stability conditions, resolution, temperature units, date and time to meet measurement requirements.
Reset function can resumes all settings to factory default values.
Expanded memory stores and recalls up to 500 readings.
Built-in real-time clock stamps stored data to meets GLP standards.
Specifications:-
Model | LMPH12 |
Make | LABMAN |
pH Range | -2.000-20.000pH |
pH Accuracy | +0.002pH |
pH Resolution | 0.001, 0.01, 0.1pH ( Selectable) |
mV Range | +1999mV |
mV Accuracy | +0.2mV |
mV Resolution | 0.1, 1mV ( Selectable ) |
Calibration | upto 5 points |
pH Buffer Option | USA (pH1.68,4.01,7.00,10.01,12.45), NIST (pH1.68,4.01,6.86,9.18,12.45) DIN (pH1.09,4.65,6.79,9.23,12.7) OR User Define |
Calibration due reminder | |
Temp. Range | 0-105°C, 32-212°F |
Temp. Accuracy | +0.5°C, +0.9°F |
Temperature Compensation | 0-100°C, 32-212°F, Automatic or Manual |
Auto-Off | Manual or Automatic (10, 20, 30 minutes after last key pressed (Selectable) |
Memory | 500 readings with date & time |
Power Supply | Adaptor, Using AC 220V,50/60Hz |
Dimensions LxWxH (mm) | 210x188x60 |
Weight | 1.2kg |
- Regular price
- Rs.71,850.00
- Sale price
- Rs.41,850.00
Sale
Couldn't load pickup availability
- Delivery Period :3-5 Working Days
- Replacement :3 Days Replacement as standard, Free of Cost
- Dedicated Support :Support from 9:30 AM to 6:00 PM everyday

Product Description
SALIENT FEATURES:-
During the pH mode, Up to 5 points push-button calibration with auto- buffer recognition.
Selectable pH buffer standards and temperature units.
Automatically calculates and displays electrode slope after calibration.
Automatic Temp. Compensation (ATC) ensures highly accurate measurement over the entire range.
Calibration due reminder prompts you to calibrate the meter regularly.
During ORP mode, Single point offset calibration allows user adjusts displayed value to a known standard.
Absolute or Relative millivolt (R.mV) measurement provides accurate ORP readings.
Automatic endpoint function freezes the stable measured values for easy reading and recording data.
Setup menu lets user customizes buffer standards,
calibration points, stability conditions, resolution, temperature units, date and time to meet measurement requirements.
Reset function can resumes all settings to factory default values.
Expanded memory stores and recalls up to 500 readings.
Built-in real-time clock stamps stored data to meets GLP standards.
Specifications:-
Model | LMPH12 |
Make | LABMAN |
pH Range | -2.000-20.000pH |
pH Accuracy | +0.002pH |
pH Resolution | 0.001, 0.01, 0.1pH ( Selectable) |
mV Range | +1999mV |
mV Accuracy | +0.2mV |
mV Resolution | 0.1, 1mV ( Selectable ) |
Calibration | upto 5 points |
pH Buffer Option | USA (pH1.68,4.01,7.00,10.01,12.45), NIST (pH1.68,4.01,6.86,9.18,12.45) DIN (pH1.09,4.65,6.79,9.23,12.7) OR User Define |
Calibration due reminder | |
Temp. Range | 0-105°C, 32-212°F |
Temp. Accuracy | +0.5°C, +0.9°F |
Temperature Compensation | 0-100°C, 32-212°F, Automatic or Manual |
Auto-Off | Manual or Automatic (10, 20, 30 minutes after last key pressed (Selectable) |
Memory | 500 readings with date & time |
Power Supply | Adaptor, Using AC 220V,50/60Hz |
Dimensions LxWxH (mm) | 210x188x60 |
Weight | 1.2kg |
Similar Products
-
Sale
Vendor: Systonic
Auto Salinity-Temp. Meter S-947
Sale price Rs.8,000.00Regular price Rs.13,900.00 -
Sale
Vendor: Systonic
Microprocessor pH-Cond. MV-Temp Meter S- 904
Sale price Rs.14,000.00Regular price Rs.23,000.00 -
Sale
Vendor: Systonic
Systonic Portable TDS Meter S- 946
Sale price Rs.4,400.00Regular price Rs.7,400.00 -
Sale
Vendor: Systonic
Auto Conductivity TDS Temp Meter-S-950
Sale price Rs.8,000.00Regular price Rs.13,999.00
Customers also bought
Complementary products
-
Free Shipping
Orders above Rs. 1000.
-
On Time Delivery
Within 7 days.
-
Money Back Guarantee
14 day Return*
-
Service Support
Online Installation Support.